The precision triaxial head allows you to set the non-contact/contact probes to a posture at a desired angle. |
 |
The 3rd axis on the apex of the triaxial head selects the optimum direction of the laser line light when the non-contact probe is used. This ensures high precision measurement. With the contact probe, it is possible to rotate the L-type probe, reducing the number of required probes and the frequency of probe replacements. |
 |
With the stepless rotation mechanism, you can easily register several contact probes in a short time. (The precision triaxial head enables measurements at any position with several registrations, even when a new probe is created.) |
 |
|
 |
 |
 |
 |
 |
 |
 |
|
|
 |
| L-Scan CNC System |
| Stroke |
Arm axis: 1500mm Base axis: 6000mm Column axis: 2700mm |
| Rotation angle |
HA axis: 0°- +180° HBHC axis: 0°- +150° HC axis: 0°- ±180° |
| Rotation speed |
Each axis:30°/second |
| Speed |
JS mode: 0 - 6,000mm/min CNC mode: 0 - 12,000mm/min Search mode: 0 - 600mm/min |
| Precision
|
U3: 35+35L/1000[μm] |
|
 |
|
 |
 |
 |
 |
 |
High torque motor head capable of positioning in 720 direction.
The motorized probe head position the probe angle in 720 direction with a high reproducibility.
Since a 300 m extension bar and 450 mm carbon extension bar can be used, it is easy to access workpieces difficult to measure. (Note: Use of a 450 mm extension bar slightly decreases precision)
Link with the auto probe charger (ACR1 (8 stations) or ACR3 (4 stations) and selection of a probe well suited to measurement will improve work efficiency. |
 |
|
 |
 |
 |
|